<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>15364</ErrorNumber>
<ErrorFamily>Autoloader</ErrorFamily>
<ErrorMessage>
ALE: STEP : axis 1 timed out while moving
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Trendsetter_400/800_Proofing</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<OperatorAction>
<DescriptionText><text>
Select RESUME from the workstation dialog box.  If that doesn't correct the
problem, make sure that the vacuum roller is not obstructed and try
again. If the problem persists,  call Creo service.
</text></DescriptionText>
</OperatorAction>
<ServiceInformation>
<DescriptionText><text>
This error occurs when the stepper motor takes longer to complete a MOVE or JOG
command than the time specified by the "altim cmd" parameter.  This happens if
the traveller is obstructed, if the stepper motor or amplifier is damaged, if
the timeout is set too short, or if the motor speed values are incorrect.
</text></DescriptionText>
<DescriptionText><text>
The sensor status may be checked by using the TABLE command. The sensor status
should read TRUE if the sensor is activated.
</text></DescriptionText>
</ServiceInformation>
<Cause>
The vacuum roller is obstructed.
</Cause>
<Cause>
The stepper motor or drive amplifier is faulty.
</Cause>
<Cause>
The timeout value ("altim cmd") is incorrect.
</Cause>
<Cause>
The motor speed parameters ("aldrv 1 fr") are set incorrectly.
</Cause>
<Cause>
The sensor wiring is faulty.
</Cause>
<Cause>
The gears or chain are loose or broken.
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../commands/resume.xml</LinkAddress><LinkTitle>Command: resume</LinkTitle></Link>
<Link><LinkAddress>../nvs/altim_cfg_cmd.xml</LinkAddress><LinkTitle>NVS: altim cmd</LinkTitle></Link>
<Link><LinkAddress>../nvs/aldrv_cfg_fr.xml</LinkAddress><LinkTitle>NVS: aldrv fr</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:33:04 2008 PST
</Updated>
<Links>
</Links>
</Error>